Model Number : XRW-300BT-Ⅵ
Product Category : HDT VICAT Testing Machine
Certification : ISO9001, CE
Test Standards : ISO75-1, ISO306, GB/T8802, GB/T1633, GB/T1634, ASTM D 1525-1991, ASTM D648-06
MOQ : 1 set
Packaging Details : Standard export wooden cases
Current Source : 4KW, 220VAC, 50HZ
Supply Ability : 15 sets per month
Test Stations : 6
Delivery Time : 5~10 work days
Maximum Deformation Measurement Error : 0.01mm
Payment Terms : T/T,L/C,D/A,D/P,Western Union
Deformation Measurement Range : -1.00~10.00mm
Place of Origin : BEIJING, CHINA
Heating Medium : Silicone oils, glycerine, ethylene glycol, mineral oil
Brand Name : JINHAIHU
Product Name : HDT VICAT Testing Machine apparatus for determining thermal deformation and softening characteristics of various plastic materials
Thermal Deformation Temperature (HDT): Defined as the temperature at which a material sample exhibits a pre-specified degree of deformation under a given applied load and constant temperature rise rate. This measurement indicates the thermal stability performance of the material under sustained loading conditions.
Vicat Softening Point: The temperature at which a weighted needle penetrates 1mm into a plastic test specimen under standardized testing conditions. This demonstrates the heat resistance performance of the material when subjected to combined heat and force.
Thermal Deformation Temperature Testing: The test specimen is placed on a support with a designated span, a specified load is applied, and the assembly is placed in a progressively heating environment. When the sample deformation reaches the designated value, the recorded temperature is the thermal deformation temperature.
Vicat Softening Point Testing: The test specimen is immersed in a heating medium, and a standard pressure needle is pressed against the sample under a given load. When the pressure needle penetrates 1mm into the specimen, the recorded temperature is the Vicat softening point.
| Parameter | Specification |
|---|---|
| Model | XRW-300BT-Ⅵ |
| Temperature control range | Room temperature ~300℃ |
| Maximum temperature error | ±0.5℃ |
| Heating rate | 50℃/h, 120℃/h, or set between 50-120℃/h |
| Temperature measurement point | 1 |
| Test frame number | 6 |
| Range of deformation measurement | -0.1~10mm |
| Maximum deformation error | ±0.005mm |
| Deformation resolution | 0.001mm |
| Sample supports span | 64mm, 100mm |
| Load bar and press (needle) weight | 74g |
| Voltage and power | 220V, 6KW |
| Thermal expansion coefficient of sample itself | <0.005/100℃ |
| Working medium | Methylsilicone oil or transformer oil |
| Cooling-down method | Natural cooling above 150℃, water cooling below 150℃ or natural cooling |